Measure the magnetic susceptibility and / or conductivity of rock samples or drill cores.
The KT-20 is a handheld console with different modules for measuring the
magnetic susceptibility, conductivity, chargeability & resistivity, and
density of a sample.
Calibration and Reference Pads for:
• Magnetic Susceptibility
• Conductivity
• IP/Resistivity
A range of magnetic susceptibility calibration pads, conductivity reference pads, and an IP/resistivity reference pad are available for the KT-10 and/or KT-20 instruments.
The purpose of the pads is to confirm that a KT-10 or KT-20 is operating within its specifications, ensuring the measurements
are accurate and reliable.

The KT-10 meters are a line of handheld instruments that measure the magnetic susceptibility "S" and/or conductivity "C" of a geological sample or core.
Both configurations are also equipped with a host of features that include an extended magnetic susceptibility measurement range, the ability to present users with an iron ore concentration estimate, input depth correlation information and a correction for split and full cores. The ability to input information to correlate measurements to their appropriate depths, a built-in microphone to record voice notes, and the GeoView data management/visualization
software.
The meters are available in circular and rectangular coil designs to measure large or small sized samples, respectively.
With its compact and rugged design, the KT-10 meters are ideal instruments for use in the field, core shack, or lab.
The KT-20 is a handheld console with different modules for measuring the magnetic susceptibility, conductivity, chargeability & resistivity, and density of a sample. Its modular design allows the KT-20 to be available in
many configurations of measurement capabilities, and new modules or upgrades can be added at anytime.
A range of sensors with different shapes and frequencies are available for the KT-20. Users can interchange the sensors on the console, allowing the KT-20 to be adapted to different
sizes and types of samples, or used in various applications.
The KT-20 console includes a number of built-in features to increase the amount of information that can be added to a measurement record. These features include a GPS receiver to obtain coordinates of the measurement, digital camera to photograph the sample, a microphone to record voice notes,
and a virtual keyboard to enter text notes.
A range of magnetic susceptibility calibration pads, conductivity reference pads, and an IP/resistivity reference pad are available for the KT-10 and/or KT-20 instruments. The purpose of the pads is to confirm that a KT-10 or KT-20 is operating within its specifications, ensuring the measurements are accurate and reliable. The calibration pads have the added benefit of being able to recalibrate a KT-10 or KT-20 with magnetic susceptibility activated. The magnetic susceptibility and conductivity pads come in flat and curved designs to accommodate instruments with different coil/sensor shapes, and with varying nominal values to confirm the instrument’s accuracy within different ranges. Although the pads are designed for the KT-10 and KT-20 systems, they are also compatible with other instruments. Each magnetic susceptibility and conductivity pad is delivered with a test certificate confirming their nominal value and homogeneity.
Magnetic Susceptibility Calibration Pads
The calibration pads are to recalibrate any KT-10 or KT-20 that is capable of measuring magnetic susceptibility. They also serve as a check source to confirm the instrument’s measurements are accurate. The pads are available in flat and curved designs.
Conductivity Reference Pads
The conductivity reference pads are check sources for any KT-10 or KT-20 that is capable of measuring conductivity. The pads are available in flat and curved designs. Every conductivity reference pad has their absolute values measured by two methods. The first is the contact measurement of the electrical resistivity of the pad based on the plazmochemical deposition of Ah on its top and bottom surfaces. The second method is the standard four-point contact method.
IP-T10 IP/Resistivity Reference Pad
The IP-T10 is a reference pad to verify the KT-20 IP/Resistivity Module’s various measurement parameters. Its housing is shaped like a drill core and made from polished granite to minimize the influence of any surface contamination. The IP-T10 is compatible with both the small and large KT-20 IP sample holders. It is delivered with a factory test certificate.




Copyright © Alla rättigheter förbehållna